LOW PRESSURE "AN" TORCHES

The AN torches are low gas pressure torches designed to deliver a low velocity flame for general heating applications. The required gas pressures are between 1-7 kPa and all torches are supplied with a gas control valve.

The AN torches induce between 25% and 50% of the total air from the inspirator depending primarily on the gas pressure and the draw. Max. input per combustion space volume is 20-50 MJ/Hour/28 litres (20,000 - 40,000 Btu/f3).

 

an-torch.jpg (12601 bytes)

MODEL NUMBER

SIZE (BSP)

FLAME LENGTH (mm)

OVER ALL LENGTH (mm)

CAPACITY RANGE MJ/HOUR

WEIGHT KG

TH-AN1

15mm

150

240

8 - 20

.30

TH-AN2

20mm

200

330

15 - 40

.55

TH-AN3

25mm

300

390

25 - 70

1.0

TH-AN4

32mm

350

490

40 - 100

2.0

TH-AN5

40mm

400

570

60 - 140

2.4

TH-AN6

50mm

450

605

100 - 200

4.4

TH-AN7

65mm

550

730

145 - 300

6.4

TH-AN8

80mm

600

830

220 - 450

8.5

TH-AN9

100mm

700

970

305 - 850

13.0

DRAFT MULTIPLIER TABLE

Capacities of the AN torch can be increased, using the following multipliers, for applications such as air heating, where there is a draft produced. 

DRAFT INCHES W.C.

0.01

0.05

0.1

0.2

0.3

0.4

0.5

0.6

0.8

1.0

CAPACITY MULTIPLIER

.40

.75

1.0

1.4

1.7

2.0

2.2

2.4

2.8

3.2

Click here to return to Torch Burner index.